Thermo Scientific™ Remel McFarland Equivalence Turbidity Standard is packaged in plastic case with a visual comparison card.
Tubing Size | 15 x 103 mm |
---|
Designed for quick and easy turbidity measurement in the laboratory
Generate an accurate turbidity reading quickly with the Thermo Scientific™ Orion™ AQUAfast AQ3010 Turbidity Meter
Waterproof, portable, infrared Turbidity meter wtih extended range up to 2000 NTU, 0.01 resolution
Utilize dual LED light sources and drinking water/wastewater methods approved for U.S. EPA regulatory reporting offered by this turbidity meter.
Type | Turbidity Meter |
---|---|
Battery Life | 2500 Hours |
Description | Turbidimeter and Calibration Kit |
Display Type | LED |
EPA Approved Methods | 180.1 |
Automatic Range Selection | Yes |
ISO Accepted Methods | ISO 7027 |
Certifications/Compliance | US EPA approval for Drinking Water Reporting per 40 CFR Part 141, vol. 74, no. 147, Monday, August 3, 2009. Rules and regulations pg 38351-38356.EPA 180.1 and ISO 7032 |
Light Source | LED, Multiple |
Velp Scientifica™ TB1 Turbidimeter that measures the turbidity of aqueous samples simply and accurately.
High accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory.
Simple, display-prompted push-button calibration
Measures turbidity of cell suspensions in a variety of life science applications. Grant Instruments™ Densitometer is designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 McFarland units (DEN-1) 0.0 to >7.5 McFarland units (DEN-1B) with a small standard deviation.
Height (Metric) | 75 mm |
---|---|
Electrical Requirements | Input AC 120/230V 50/60 Hz Output DC 12 V |
Sample Size | ≥2 |
Dimensions (L x W x H) | 115 x 165 x 75 mm |
Precision | ±3% |
Voltage | 12 V |
Temperature (Metric) Operating | 4°C to 40°C |
Light Source | LED |
Width (Metric) | 165 mm |
Weight (Metric) | 0.7 kg |
Three-point calibration automatically with user guidance and calibration and documentation
The WTW™ VisoTurb™ 900-P IDS IR Turbidity Sensor is designed for digital IDS turbidity measurement for field applications in surface waters and process samples.
With an accuracy of 0.01 NTU or ±2% of the measured value; these portable turbidity meters are ideal for all applications including drinking water testing, environmental monitoring, laboratory reference measurements and process control.
Height (Metric) | 86 mm |
---|---|
Accuracy | 0.01 NTU or ±2% of the measured value |
Sample Size | 20 mL |
Warranty | 2 Years |
Length (Metric) | 117 mm |
Display Type | LCD |
IP Rating | IP67 |
Temperature (Metric) Operating | 0°C to 50°C |
For Use With (Application) | Used for all applications including drinking water testing, environmental monitoring, laboratory reference measurements and process control |
Battery Type | 4 x AA |
Weight (Metric) | 0.6 kg |
Resolution | 0.01 from 0.00 to 9.99, 0.1 from 10 to 99.90, 1 from 100 to 1100 |
Ensure your turbidity meter has the accessories it needs, including turbidity vials, primary turbidity standards, Formazin turbidity standards, and more.
Dedicated Calibration Set for the WTW™ Turb™ 555T Turbidity Meter includes indexing rings and cleaning tissues
Replacement items for Oakton T100 Turbidity meter