UserName
Analyze toxic dioxins and furan congeners with unsurpassed performance and reproducibility.
Stationary Phase | TraceGOLD TG-Dioxin |
---|---|
Description | TG-Dioxin GC Columns |
Product Line | TraceGOLD |
Employ the most widely used MS phase in gas chromatography with the Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
SGE GC column BP5MS is an optimized silphenylene column for general purpose MS analysis
Max. Temperature | 350°C |
---|---|
Description | GC Capillary column |
Temperature Range | -40°C to +330/350°C |
Material | 5% Phenyl Polysilphenylene-siloxane |
For Use With (Application) | 5% GC-MS Analysis |
SGE BP624 GC Capillary Columns - A polar phase designed for EPA volatile organics analysis
Max. Temperature | 230/240°C |
---|
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Max. Temperature | 220°C (long term), 240°C (in temperature program) |
---|---|
Type | GC Capillary Column |
Stationary Phase | Permabond™ CW 20 M |
Packing Material | Poly(ethylene glycol) |
Diameter (Metric) | 0.5 mm |
Diameter (Metric) Inner | 0.32 mm |
Quantity | 1 Each |
Functionality/Interaction Type | Polar phase |
USP Type | G16 |
SGE BPX70 GC Capillary Column is an MS premium, low bleed column with high polarity specifically designed for fatty acid methyl ester (FAME) analysis
Max. Temperature | 250/260°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | BPX70 |
Temperature Range | 50°C to 250/260°C |
Designed for separation of components according to boiling points. Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.5mm O.D., Thick Film are non-polar phase columns with 100% dimethylpolysiloxane for use in gas chromatography. Available in a range of lengths and film thicknesses.
Type | High Performance GC Capillary Column |
---|---|
Stationary Phase | Optima™ 1 |
Diameter (Metric) | 0.5 mm |
Diameter (Metric) Inner | 0.32 mm |
Quantity | 1 Each |
Temperature Range | 300°C to 320°C |
For Use With (Application) | Separation of Components According to Boiling Points Analysis |
USP Type | G1, G2, G38 |
Used for EPA volatile organics analysis. Trajan Scientific and Medical BP624 GC Capillary Columns are polar phase designed columns.
Type | BP624 GC Capillary Column |
---|---|
Length (Metric) | 60 m |
Packing Material | BP624 |
Temperature Range | 0°C to 230/240°C |
Material | Cyanopropylphenyl Polysiloxane |
Ideal for MSD and PND detectors. Macherey-Nagel™ OPTIMA™ δ-3 Capillary Columns for GC are polysiloxane phase columns with autoselective polarity. The analytes determine the polarity of the phase. Available in a range of diameters, lengths and film thicknesses.
Type | GC Capillary Column |
---|---|
Stationary Phase | Optima™ d-3 |
For Use With (Equipment) | Ideal for MSD and PND Detectors |
Quantity | 1 Each |
For Use With (Application) | Gas Chromatography (GC) |
USP Type | G49 |
Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ B Capillary Columns for GC are phases with six α-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase.
Max. Temperature | For isothermal operations: 200°C, For short isotherms in a temperature program: 220°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Lipodex™ B |
Packing Material | Lipodex™ B |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Polarity | Non polar |
For Use With (Application) | Enantiomer Separation |
Ideal for analyses such as hydrocarbons, aromatics, pesticides and amines.
Suitable for all routine analysis. Trajan Scientific and Medical BP1 PONA GC Capillary Columns are industry standard non polar phase columns.
Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ G Capillary Columns for GC are phases with eight γ-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase.
Max. Temperature | For isothermal operations: 220°C, For short isotherms in a temperature program: 240°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Lipodex™ G |
Packing Material | Lipodex™ G |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Polarity | Non polar |
For Use With (Application) | Enantiomer Separation |