missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Thermo Scientific™ SPDP (succinimidyl 3-(2-pyridyldithio)propionate)
Shop All Thermo Scientific ProductsDescription
Thermo Scientific™ Pierce SPDP is a short-chain crosslinker for amine-to-sulfhydryl conjugation via NHS-ester and pyridyldithiol reactive groups that form cleavable (reducible) disulfide bonds with cysteine sulfhydryls.
Highlights:
- Widely used in immunochemistry; conjugates used in drug carrier systems, antibody production and enzyme immunoassays
- Can be used as a protein thiolation reagent
- Reactive groups: NHS ester and pyridyldisulfide
- Reactive toward: amino and sulfhydryl groups
Specifications
Specifications
| Chemical Reactivity | Amine-Sulfhydryl |
| Cleavable | By Thiols |
| Description | SPDP |
| Molecular Weight (g/mol) | 312.36 |
| PEGylated | No |
| Spacer Arm Length | 6.8 Å |
| Content And Storage | Upon receipt store at -20°C protected from moisture. |
| Cell Permeability | Yes |
| Shipping Condition | Ambient |
| Product Line | Pierce |
| Show More |
Safety and Handling
Product Identifier
- SPDP (succinimidyl 3-(2-pyridyldithio)propionate)
- Warning
- Serious eye damage/eye irritation Category 2
- Skin corrosion/irritation Category 2
- Specific target organ toxicity Category 3
- H315-Causes skin irritation.
- H319-Causes serious eye irritation.
- H335-May cause respiratory irritation.
- P261-Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264-Wash hands thoroughly after handling.
- P271-Use only outdoors or in a well-ventilated area.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352-IF ON SKIN: Wash with plenty of water/soap.
- P304+P340-IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P312-Call a POISON CENTER/doctor/if you feel unwell.
- P332+P313-If skin irritation occurs: Get medical advice/attention.
- P337+P313-If eye irritation persists: Get medical advice/attention.
- P362+P364-Take off contaminated clothing and wash it before reuse.
- P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
- MIXTURE LIST-Contains : 1-[1-Oxo-3-(2-pyridyldithio)pro poxy]pyrrolidine-2,5-dione
For Research Use Only. Not for use in diagnostic procedures.
Product Title
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.
Spot an opportunity for improvement?