METTLER TOLEDO™ Ion Selective Electrodes (ISE)

Product Code. 10145642 Shop All Mettler Toledo Products
Change view
Click to view available options
Connector Types:
BNC
S7 BNC Cable
Model:
perfectION Ag+/S2- Combination Electrode
perfectION CI- Combination Electrode
perfectION CN- Combination Electrode
perfectION CU2+ Combination Electrode
perfectION Ca+2 Combination Electrode
perfectION DX223-Na+ Half-Cell Electrode
perfectION DX235-Cl- Half-Cell Electrode
perfectION FI- Combination Electrode
perfectION I- Combination Electrode
perfectION K+ Combination Electrode
perfectION NO3- Combination Electrode
perfectION Na+ Combination Electrode
perfectION Pb2+ Combination Electrode
Measurement Range:
0.002 to 23000 mg/L
0.005 to 127000 mg/L
0.02 mg/ - saturated solution
0.02 to 40100 mg/L
0.04 to 39000 mg/L
0.1 to 14000 mg/L
0.2 to 20700 mg/L
0.2 to 260 mg/L
1.0 to 1 x 10-7 mol/L
1.0 to 1.0-5 mol/L
1.8 to 35500 mg/L
6.4 x 10-6354 mg/L
Ag+: 0.01 to 108000 mg/L; S2-: 0.003 to 32000 mg/L
Unit Size:
Each
Product Code. Connector Types Model Measurement Range unitSize
10145642 S7 BNC Cable perfectION DX223-Na+ Half-Cell Electrode 1.0 to 1 x 10-7 mol/L Each
11987811 BNC perfectION CI- Combination Electrode 1.8 to 35500 mg/L Each
11977811 BNC perfectION Ca+2 Combination Electrode 0.02 to 40100 mg/L Each
11997811 BNC perfectION CN- Combination Electrode 0.2 to 260 mg/L Each
11907821 BNC perfectION CU2+ Combination Electrode 6.4 x 10-6354 mg/L Each
11967811 BNC perfectION Ag+/S2- Combination Electrode Ag+: 0.01 to 108000 mg/L; S2-: 0.003 to 32000 mg/L Each
10566415 BNC perfectION FI- Combination Electrode 0.02 mg/ - saturated solution Each
11927821 BNC perfectION I- Combination Electrode 0.005 to 127000 mg/L Each
11947821 BNC perfectION NO3- Combination Electrode 0.1 to 14000 mg/L Each
11937821 BNC perfectION K+ Combination Electrode 0.04 to 39000 mg/L Each
11917821 S7 BNC Cable perfectION Na+ Combination Electrode 0.002 to 23000 mg/L Each
10067810 S7 BNC Cable perfectION DX235-Cl- Half-Cell Electrode 1.0 to 1.0-5 mol/L Each
11957821 BNC perfectION Pb2+ Combination Electrode 0.2 to 20700 mg/L Each
13 options
This item is not returnable. View return policy

Product Code. 10145642

Brand: METTLER TOLEDO™ 51340263

Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

A selection of ISE probes for detecting concentration of various free ions.

  • Prior to first use, rinse the electrode with distilled water and soak it in the appropriate standard for 24-48 hours and then fill with reference electrolyte (refer to table above)
  • ISA (Ionic strength adjuster) solution required to be added to all calibration standards and samples prior to measurement for accurate results
  • Refer to electrode user manual for appropriate ratio of ISA solution to sample volume
  • Add filling solution each day before using the electrode (at least 2.5 cm above sample level in beaker)
  • Be sure to screw cap tightly immediately after use
  • The filling solution inside the electrode should not be allowed to evaporate, as crystallization will result
  • For storage between measurements and up to three days, store in the appropriate standard
  • For long-term storage, refer to specific ISE electrode user manual
  • Sensing membrane will wear over time; each membrane can last about six months with normal use, but actual lifespan will depend on the type of samples that are being measured
  • Competing ion interferences are common. Refer to ISE electrode user manual for potential interferences
  • Compatible with METTLER TOLEDO SevenExcellence Benchtop, Seven2Go, and SevenGo Portable
  • Compatible with InMotion Autosampler to automate measurement and cleaning of up to 303 samples
TRUSTED_SUSTAINABILITY

Specifications

Connector Types S7 BNC Cable
Description Required Solutions: Reference Electrolyte - 0.1 mol/L NH4Cl Ionic Strength Adjuster - NH4Cl /NH4OH
Filling Solution Type NH4Cl/NH4OH (ISA)
Length (English) 4.75 in.
Length (Metric) 120 mm
Material Epoxy
pH Range 8 to 11
Model perfectION DX223-Na+ Half-Cell Electrode
Temperature (Metric) Operating 0°C to 80°C
Type Ion Selective Electrode
Measurement Range 1.0 to 1 x 10-7 mol/L
Parameter Sodium
Show More Show Less