Capacity (Metric):
32 L
53 L
74 L
108 L
161 L
256 L
449 L
749 L
Depth (Metric) Outside:
434 mm
514 mm
584 mm
684 mm
784 mm
Depth (Metric) Chamber:
250 mm
330 mm
400 mm
500 mm
600 mm
Height (Metric) Exterior:
704 mm
784 mm
864 mm
944 mm
1104 mm
1183 mm
1247 mm
1726 mm
Unit Size:
Each
Product Code. Capacity (Metric) Depth (Metric) Outside Depth (Metric) Chamber Height (Metric) Exterior unitSize
12885863 449 L 784 mm 600 mm 1247 mm Each
12855863 108 L 584 mm 400 mm 864 mm Each
12875863 161 L 584 mm 400 mm 1104 mm Each
12865863 256 L 684 mm 500 mm 1183 mm Each
12815863 32 L 434 mm 250 mm 704 mm Each
12835863 53 L 514 mm 330 mm 784 mm Each
12895863 749 L 784 mm 600 mm 1726 mm Each
12845863 74 L 514 mm 330 mm 944 mm Each
8 options
This item is not returnable. View return policy

Product Code. 12885863

Brand: Memmert™ SF450

Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

Use this vacuum sterilizer for a variety of applications. Memmert™ Forced-air Circulation Hot Air Sterilizer with TwinDISPLAY sterilizes containers and instruments. Safer than disinfection.

  • 1 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • SingleDISPLAY: Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-color displays
  • German, English, Spanish, French, Polish, Czech, Hungarian language settings
  • Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
  • Process time does not start until the set temperature is reached
  • Three freely selectable temperature values
  • Adjust by temperature (Celsius or Fahrenheit), fan speed, air flap position, program time, time zones, summertime/wintertime
  • Forced air circulation by quite air turbine, adjustable in 10% steps for each segment individually
  • Vent connection with restrictor flap
  • AtmoCONTROL software on a USB stick for programming, managing and transferring programs via Ethernet interface or USB port
  • Visual and acoustic alarms

Specifications

Certifications/Compliance 12 880: 2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010 and 61010-2-40, CE
Depth (Metric) Outside 784 mm
Capacity (Metric) 449 L
Depth (Metric) Chamber 600 mm
For Use With (Application) Applied for sterilisation of medical materials, complete killing of highly resistant microorganisms, special application of depyrogenisation
Height (Metric) Exterior 1247 mm
Model SF450
Temperature (Metric) 10°C to 250°C
Display LED
Electrical Requirements 4 V 3 phases/N 50/60Hz
Height (Metric) Interior 720 mm
Includes Works calibration certificate for 160°C
Frequency 50/60 Hz
Interface Ethernet and USB
Material Stainless Steel, Zinc-plated Steel
Voltage 400 V
Wattage 5.8 kW
Width (Metric) Exterior 1224 mm