HPLC Columns
- (1)
- (9)
- (281)
- (599)
- (1)
- (169)
- (3)
- (853)
- (1)
- (61)
- (33)
- (8)
- (748)
- (178)
- (46)
- (6)
- (5)
- (1)
- (5)
- (14)
- (633)
- (11)
- (2)
- (1)
- (30)
- (6)
- (17)
- (1)
- (5)
- (29)
- (8)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (2)
- (10)
- (99)
- (2)
- (1)
- (233)
- (1)
- (1)
- (2)
- (3)
- (193)
- (687)
- (1)
- (1)
- (146)
- (1)
- (2)
- (31)
- (8)
- (83)
- (445)
- (1)
- (106)
- (2)
- (400)
- (28)
- (954)
- (2)
- (2)
- (92)
- (2)
- (2)
- (11)
- (1)
- (20)
- (35)
- (1)
- (21)
- (14)
- (5)
- (23)
- (72)
- (96)
- (326)
- (41)
- (8)
- (8)
- (4)
- (37)
- (39)
- (17)
- (196)
- (10)
- (39)
- (1)
- (819)
- (2)
- (2)
- (1)
- (50)
- (2)
- (1,787)
- (12)
- (2)
- (63)
- (3)
- (23)
- (6)
- (5)
- (17)
- (7)
- (1)
- (1)
- (753)
- (2)
- (2)
- (6)
- (66)
- (1)
- (420)
- (470)
- (213)
- (224)
- (106)
- (13)
- (601)
- (5)
- (68)
- (16)
- (5)
- (8)
- (12)
- (88)
- (172)
- (13)
- (4)
- (6)
- (16)
- (197)
- (1)
- (10)
- (2)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (40)
- (1)
- (132)
- (35)
- (12)
- (187)
- (2)
- (1)
- (2)
- (13)
- (188)
- (48)
- (1)
- (11)
- (122)
- (2)
- (8)
- (2,464)
- (9)
- (21)
- (12)
- (10)
- (8)
- (2)
- (96)
- (11)
- (47)
- (13)
- (4)
- (4)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
| Carbon Load | 11% |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypersil™ ODS-2 C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes separated under difficult operating conditions.
| Pore Size | 80 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous Type A Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| Product Line | Hypersil Classical |
| USP Type | L1 |
Thermo Scientific™ Single nanoViper™ and Double nanoViper™ PepMap™ Neo UHPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Separate challenging peptide mapping samples with Thermo Scientific™ Double nanoViper™ PepMap™ Neo UHPLC columns.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 2 μm |
| Carbon Load | 15% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| For Use With (Application) | Peptide Mapping, LC-MS |
| Max. Pressure | 22,000 psi (1500 bar) |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ Phenyl HPLC Columns
Use for quick analysis of aromatic analytes, including glucocorticosteroids, estrogens, fat-soluble vitamins, and phospholipids.
| Pore Size | 175 Å |
|---|---|
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| USP Type | L11 |
Thermo Scientific™ Hypersil GOLD™ C4 HPLC Columns
Featuring a lower hydrophobicity than C18 or C8 columns, Thermo Scientific™ Hypersil GOLD™ C4 columns provide outstanding sensitivity and high efficiency.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 5% |
| Stationary Phase | C4 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| USP Type | L26 |
Thermo Scientific™ µPAC™ Neo HPLC Columns
Learn more about your proteome samples with Thermo Scientific™ μPAC™ Neo Plus HPLC columns.
| Pore Size | 100 to 300 Å |
|---|---|
| Stationary Phase | C18 |
| Endcapped | Yes |
| Packing Material | Silicon Chip |
| pH | 1.5 to 7 |
| Max. Pressure | 6526 psi (450 bar) |
Thermo Scientific™ Acclaim™ Polar Advantage II HPLC Columns
Resolve polar and nonpolar compounds in a single run. These columns have high pH stability (pH 1.5–10) in the separation of basic, neutral, and acidic species.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Polar Embedded |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Column Type | Reversed Phase |
| Surface Area | 300 m²/g |
| USP Type | L60 |
Thermo Scientific™ Syncronis™ Silica HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Syncronis Silica LC Columns.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | Silica |
| Temperature | 60°C |
| Phase | Normal Phase |
| Column Type | Normal Phase |
| pH | 2 to 8 |
| Surface Area | 320 m²/g |
| USP Type | L3 |
Thermo Scientific™ HyPURITY™ ADVANCE™ HPLC Columns, 5μm Particle Size
Use this specialty C8 column for separating compounds showing poor peak shape with traditional alkyl bonded phases.
| Particle Size | 5 μm |
|---|---|
| Carbon Load | 9% |
| Stationary Phase | C8 |
| Phase | Reversed Phase |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| Surface Area | 200 m²/g |
| USP Type | L7 |
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Retain and resolve polar analytes with highly aqueous mobile phases.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 12% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Polar |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 220 m²/g |
| USP Type | L1 |
Thermo Scientific™ BioBasic™ AX HPLC Columns
Use Thermo Scientific™ BioBasic™ AX LC Columns for the separation of proteins, peptides, other anionic species and highly polar molecules.
| Pore Size | 300 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 3% |
| Stationary Phase | Polyethyleneimine |
| Temperature | 60°C |
| pH | 2 to 8 |
| Surface Area | 100 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
Thermo Scientific™ Hypersil GOLD™ Cyano HPLC Columns
Alternate selectivity with lower hydrophobicity. Use these HPLC columns for normal and reversed phase separations.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 4% |
| Stationary Phase | Cyano (CN) |
| Temperature | 60°C |
| Phase | Normal and Reversed Phase |
| Endcapped | Yes |
| Column Type | Mixed Mode |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| USP Type | L10 |