Thermo Scientific™ TR-FRET Coregulator Buffer A

Artikelnummer. 10562704
Skift visning
Klik for at se tilgængelige muligheder
Quantity:
25 mL
Pakningsstørrelse:
Each
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Quantity Pakningsstørrelse
10562704 25 mL Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Denne vare kan ikke returneres. Se returpolicy
Artikelnummer. 10562704 Leverandør Thermo Scientific™ Leverandørnr. PV4384
 Restricted Item
Estimated Shipment: 30-09-2026
Læg i indkøbskurv
Læg i indkøbskurv
Denne vare kan ikke returneres. Se returpolicy

A specialized nuclear receptor buffer that can be used with Invitrogen's collection of purified nuclear receptor proteins and assays.

A specialized nuclear receptor buffer that can be used with Invitrogen's collection of purified nuclear receptor proteins and assays.

TRUSTED_SUSTAINABILITY

Tekniske data

For Use With (Equipment) LanthaScreen™ Nuclear Receptor Cofactor Interaction Assays
Description TR-FRET Coregulator Buffer A, 25mL, Liquid, 7.5 pH, 20 to 30°C Storage, Room Temperature or on Wet or Dry Ice Shipping Conditions, Water Soluble, For use with Pharma and Biopharma, Target and Lead Identification and Validation
Content And Storage TR-FRET Coregulator Buffer A may be shipped frozen or at room temperature. Store at room temperature (20°C to 30°C).
Quantity 25 mL
Form Liquid
Shipping Condition Approved for shipment at Room Temperature or on Wet or Dry Ice
I have no assay window in my TR-FRET assay. What is the reason?

The single most common reason that a TR-FRET assay fails is that an incorrect choice of emission filters was made. Unlike other fluorescent assays, the filters used in a TR-FRET assay must be exactly those that are recommended for your instrument as the emission filter choice can make or break the assay. The excitation filter has more of an impact on the assay window. Please refer to our instrument setup guides in our instrument compatibility portal (https://www.thermofisher.com/instrumentsetup). If your instrument is not listed there, please contact Drug Discovery Technical Support at drugdiscoverytech@thermofisher.com.

Note: Test your microplate reader's TR-FRET setup before you begin any work with your assay. Using reagents that you have already purchased for your assay, you can test the microplate reader's TR-FRET setup. Please refer to the Terbium (Tb) Assay (http://tools.thermofisher.com/content/sfs/manuals/LanthaScreen_Tb_Instrument_Control_Application_Note17Sep10.pdf) and Europium (Eu) Assay (http://tools.thermofisher.com/content/sfs/manuals/Eu_Instrument_Control_AppNote_12Nov10.pdf) Application Notes for plate reader setup.

For Research Use Only. Not for use in diagnostic procedures.