missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Dräger™ Short-Term Detector Tubes: Oil Mist
Click to view available options
Components Measured:
Oil 10/a-P
Oil Mist 1/a
Measurement Range:
0.1 - 1 mg/m3
1 to 10mg/m3
Unit Size:
Pack of 10
Description
Gas detection tubes for oil mist.
6733031:
- Indicates only mineral and synthetic oil aerosols (mist)
- Standard measuring range: 1 to 10mg/m3
- No.of Strokes n: 100
- Time for measurement: approx. 25 min.
- Color change: White to brown
6728371:
- Indicates the total concentration of mineral and synthetic oil aerosols (mist) and oil vapors
- Standard measuring range: 25 to 100ug
- Color change: White to beige or yellow
Order Info
Note: Extension of measuring range listed is possible for some detector tubes. Call Fisher Customer Service for more information.
Specifications
Specifications
| Certifications/Compliance | Safety Equipment Institute (SEI) certified |
| Components Measured | Oil Mist 1/a |
| Humidity Range | Less than20mg/L |
| Measurement Range | 1 to 10mg/m3 |
| No. of Strokes | 100 |
| Quantity | 10 |
| Response Time | 25 min. |
| Temperature Range (English) | 50°F to 86°F |
| Temperature Range (Metric) | 10°C to 30°C |
Safety and Handling
Product Identifier
- X10 GAS DETECTOR TUBE DRAEGER 6733031 OIL MIST
- Warning
- Acute toxicity Category 4
- Serious eye damage/eye irritation Category 1
- Serious eye damage/eye irritation Category 2
- H302-Harmful if swallowed.
- H312-Harmful in contact with skin.
- H318-Causes serious eye damage.
- H332-Harmful if inhaled.
Product Content Correction
Your input is important to us. Please complete this form to provide feedback related to the content on this product.
Product Title
Spot an opportunity for improvement?Share a Content Correction