missing translation for 'onlineSavingsMsg'
Få mere at vide

Invitrogen™ Countess™ Reusable Slide and Holder, 1 holder

Artikelnummer. 17374933
Skift visning
Klik for at se tilgængelige muligheder
Compatibility:
Countess™ Reusable Slide (Cat. No. A5750)
Pakningsstørrelse:
Each
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Compatibility Pakningsstørrelse
17374933 Countess™ Reusable Slide (Cat. No. A5750) Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Denne vare kan ikke returneres. Se returpolicy
Artikelnummer. 17374933 Leverandør Invitrogen™ Leverandørnr. A48208
Follow the Workflow - Explore the Savings
Use promo code 27967
Se alle kampagner
 Restricted Item
Estimated Shipment: 29-12-2026
Læg i indkøbskurv
Læg i indkøbskurv

missing translation for 'validMainframeMsg'

Denne vare kan ikke returneres. Se returpolicy

Countess Cell Counting Chamber Slides are conveniently packaged for use with the Countess Automated Cell Counters. Each disposable and reusable slide features two enclosed chambers.

The Countess Chamber Slides are designed for use with the Countess 3 and 3FL automated cell counters.

The disposable Countess Cell Counting Chamber Slides offer convenience in automated cell counting for processing multiple cell samples, busy cell culture facilities, and easy disposal of contaminated or hazardous samples. They also eliminate the risk of contamination from residual samples. After use, Countess slides can be disposed of as standard biohazard waste.

The Countess Reusable Slide is a green and cost-efficient alternative to disposable slides for automated cell counting. The reusable slide enables researchers and cell culture facilities to reduce costs and generate less waste per year, making it affordable for labs to automate their cell counts. The reusable slide is cleaned and dried between counts, just as with a hemocytometer.

Each Countess Cell Counting Chamber Slide has two separate, enclosed chambers for counting one sample in duplicate or two different samples. Cell counting occurs in a central location of the counting chamber. The volume counted is 0.4 μL, the same as counting four 1-mm2 squares in a standard hemocytometer.

The Countess Automated Cell Counter works in three simple steps:

  • Mix 10 μL of sample with 10 μL of a cell viability stain or other desired reagent, including ReadyCount™ stains, and pipet into a Countess chamber slide
  • Insert the slide into the instrument
  • Press 'Count'

That's it—get the total cell count, percent viable cells, and average cell size in as little as 30 seconds.

TRUSTED_SUSTAINABILITY

Tekniske data

Type Slide Holder
Product Line Countess
Compatibility Countess™ Reusable Slide (Cat. No. A5750)
For Use With (Equipment) Countess II FL, Countess 3 & Countess 3 FL Automated Cell Counters
Content And Storage Countess™ 3 and 3 FL Reusable Slide Holder, 1 each
Quantity 1 Holder
Do you offer reusable slides and the appropriate holders for Countess II FL and Countess 3/3 FL instruments?

The Countess Reusable Slide (Cat. No. A25750) is compatible with the Countess II FL and the Countess 3/3 FL instruments. However, they require a reusable slide holder specific to the instrument. The Countess 3 & 3 FL Reusable Slide Holder (Cat. No. A48208) and the Countess II FL Reusable Slide Holder (Cat No. AMEP4746) are shipped with the instrument and can be purchased separately.

The slide holder can be held inside the back of the instrument, next to the light cube removal tool.

Where may I purchase the coverslips provided with the Countess Reusable Slide (Cat no. A25750) as a stand-alone product?

Hausser Scientific Cover Glasses/Slips (Cat. No. 02-617-581) can be purchased through Fisher Scientific; these are 20 x 26 x 0.5 mm borosilicate glass coverslips.

Can the Countess 3 & 3 FL Reusable Slide Holder (Cat no. A48208) be used on a Countess II FL Automated Cell Counter (Cat. No. AMQAF1000)?

Yes. The Countess 3 & 3 FL Reusable Slide Holder (Cat. No. A48208) be used on a Countess II FL Automated Cell Counter (Cat. No. AMQAF1000).

Can the Countess II FL Reusable Slide Holder (Cat no. AMEP4746) be used on a Countess 3 and 3 FL Automated Cell Counter (Cat. Nos. AMQAX2000 and AMQAF2000)?

Yes. The Countess II FL Reusable Slide Holder (Cat no. AMEP4746) can be used on a Countess 3 and 3 FL Automated Cell Counter (Cat. Nos. AMQAX2000 and AMQAF2000).

Can a conventional cell counting chamber be used with the Countess 3 & 3 FL Reusable Slide Holder (Cat. No. A48208)?

No. The Countess 3 & 3 FL Reusable Slide Holder (Cat. No. A48208) and the Countess instruments will only work with the Countess Reusable Slide (Cat. No. A25750). Using other slides can damage the instrument, due to differences in the height and width of the slides.

For Research Use Only. Not for use in diagnostic procedures.

Produkttitel
Vælg et problem

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.