missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Tempus™ Spin RNA Isolation Kit

This Applied Biosystems product is for the fast, easy, glass fiber filter-based isolation of RNA from blood using standard laboratory equipment in about one hour.

Brand:  Invitrogen™ 4380204

3593.51 NOK valid until 2024-03-29
Use promo code "21615" to get your promotional price.



Additional Details : Weight : 0.45000kg Transport : UN number : 1170 Chem class : 3 Pack group : II


Product Code. 11328530

  • 5390.00 NOK / Each
Estimated Shipment: 12-04-2024
to see stock.

Please to purchase this item. Need a web account? Register with us today!


Includes: RNA purification filters, 2mL collection tubes, 1X PBS, RNA Purification Resuspension Solution, RNA Purification Wash Solution 1, RNA Purification Wash Solution 2, and Nucleic Acid Purification Elution Solution

Description

Description

This Applied Biosystems product is for the fast, easy, glass fiber filter-based isolation of RNA from blood using standard laboratory equipment in about one hour. Contains sufficient reagents for RNA purification from 50 samples. Gene expression profiling and analysis of whole blood is becoming an increasingly important life science tool. Accurately measuring the molecular profile of blood-based RNA transcripts is a critical need in areas of research such as disease association studies, biomarker discovery and validation, and monitoring of drug treatment regimes.

  • Isolate high-quality RNA from blood, suitable for real-time PCR and microarray analysis
  • Obtain highly stable RNA virtually free of RNase activity, contaminating gDNA, or RT-PCR inhibitors
  • Easy workflow requires only standard laboratory centrifuges and ∼1 hour of time
  • No separate RBC lysis or proteinase K treatment required

Performance with Ease
The ability of the Tempus system (Tempus Blood RNA Tubes and Tempus Spin RNA Isolation Kit) to stabilize RNA expression profiles has been tested over a range of storage conditions. The combination provides stable RNA, high yields of purified RNA (observed yields of 6 to 25μg from a full blood draw from normal, healthy donors), and high-quality RNA (A260/280 ratio greater than 1.9 and RIN greater than 7.0) suitable for use in downstream applications such as quantitative PCR, microarray profiling, and other RNA analysis methods.

Accessory Product
The highly unstable nature of RNA transcripts ex vivo creates an even greater challenge for accurate expression analysis. Ongoing metabolic changes can drastically affect gene expression profiles in as little as one hour in standard blood collection tubes. Use of the Applied Biosystems Tempus™ Blood RNA Tubes (Cat. No. 4342792) is therefore recommended. These tubes are designed for direct collection of 3mL of blood into a plastic, evacuated blood collection tube containing RNA Stabilizing Reagent. The RNA, and therefore the expression profile, is stable in the collection tube for up to five days at room temperature and a minimum of 7 days at 4°C

Not high-throughput compatible (Manual)

Specifications

Specifications

• 50 RNA Purification Filters; room temperature
• 2 x 100 Collection Tubes; room temperature
• 2 x 80 mL 1X PBS; room temperature
• 24 mL RNA Purification Resuspension Solution; room temperature
• 2 x 22 mL RNA Purification Wash Solution 1; room temperature
• 120 mL RNA Purification Wash Solution 2; room temperature
• 4 x 1.9 mL Nucleic Acid Purification Elution Solution; room temperature

40 min.
Whole Blood
Not High-throughput Compatible (Manual)
50 Preps
Up to 3 mL of blood
Silica Spin Column
100 μL
Total RNA
RT-PCR, qPCR, cDNA library construction, NGS, microarray analysis, blot hybridization, Northern blotting, in vitro translation, nuclease protection assays, nucleic acid labeling
Room Temperature
≤25 μg
Product Suggestions

Product Suggestions

Videos
Safety and Handling

Safety and Handling

Product Identifier
  • Tempus Spin RNA Isolation Kit

Signal Word
  • Danger

Hazard Category
  • Serious eye damage/eye irritation Category 2
  • Flammable liquid Category 2
  • Skin corrosion/irritation Category 2

Hazard Statement
  • H225-Highly flammable liquid and vapour.
  • H315-Causes skin irritation.
  • H319-Causes serious eye irritation.

Precautionary Statement
  • P210-Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P233-Keep container tightly closed.
  • P242-Use only non-sparking tools.
  • P243-Take precautionary measures against static discharge.
  • P264-Wash hands thoroughly after handling.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P302+P352-IF ON SKIN: Wash with plenty of water/.
  • P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P332+P313-If skin irritation occurs: Get medical advice/attention.
  • P337+P313-If eye irritation persists: Get medical advice/attention.
  • P362+P364-Take off contaminated clothing and wash it before reuse.
  • P370+P378-In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
  • P403+P235-Store in a well-ventilated place. Keep cool.
  • P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.

Supplemental information
  • MIXTURE LIST-Contains : ethanol, Guanidine hydrochloride

SDS
Documents

Documents

Certificates
Special Offers

Special Offers

For Research Use Only. Not for use in diagnostic procedures.