Conductivity Meters
Benchtop or portable instruments and probes used to measure temperature and electrical conductivity of water or solutions; used in hydroponics, aquaculture, aquaponics, and freshwater systems to monitor quantities of nutrients, salts, or impurities.
Range (Conductivity)
- (1)
- (1)
- (1)
Range (Salinity)
- (1)
- (1)
- (1)
Data Points
- (1)
- (1)
Display Type
- (1)
- (1)
IP Rating
- (2)
Keyword Search:
flow meter
Clear all selections
Filtered Search Results
Products from some of our suppliers do not display in filtered search results. Please
clear all filters
to see these products.
1
–
3
of
3
results
Thermo Scientific™ Orion Star™ A322 Conductivity Portable Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately monitor conductivity, TDS, salinity, resistivity and temperature with this conductivity portable meter designed for challenging field tests.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 megohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Battery Life | 800 hr. |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 5000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 x AA (included) |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | Conductivity with calibration editing option and temperature |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A322 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
METTLER TOLEDO™ SevenExcellence™ S700 Conductivity Benchtop Meter
The S700 meter measures conductivity, resistivity, TDS, and salinity. Its capabilities can be expanded with additional modules to measure pH, dissolved oxygen, ISE, BOD, Redox/ORP, and ISFET. Features an intuitive touchscreen and the ability to create measurement shortcuts.
| Calibration Points | 13 Pre defined and 20 user defined standard |
|---|---|
| Temperature Compensation | 20°C |
| Range (Resistivity) | 0.01 to 100 megohm/cm |
| Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
| Accuracy (Conductivity) | ±0.5% |
| Sensor Types | Conductivity |
| Data Points | At least 20000 data points, 250 analyses |
| Range (TDS) | 0.001 mg/L to 1000 g/L |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -30°C to +130°C |
| Inputs | Integrated interfaces (USB, RS232 and Ethernet) |
| Accuracy (Temperature) | ±0.1°C |
| Range (Salinity) | 0 to 80 psu |