Conductivity Meters
Filtered Search Results
Mettler Toledo™ Protective Cover for S230 SevenCompact Conductivity Meters
Accessory for S230 SevenCompact Conductivity Meters.
Thermo Scientific™ Eutech CON 450 Handheld Meter Kit
Backlit, rugged waterproof meter is ideal for any environment
Mettler Toledo™ FiveEasy™ Plus FP30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
| Resolution (Conductivity) | Automatic range |
|---|---|
| Memory | 200 measurements, current calibration |
| Range (Conductivity) | 0.01 μS/cm to 500 mS/cm |
| Range (TDS) | 0 mg/L to 300 mg/L |
| Measurement Modes | Conductivity |
| Calibration | One point calibration with three predefined standards, manual cell constant input |
| Range (Salinity) | 0 to 42 psu |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Data Management Details | RS232 or USB ports |
| Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
| Display Type | LCD |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±0.5% of the measured value |
| Model | FP30 |
| Frequency | 50/60Hz |
| Data Points | 200 |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -5°C to +105°C |
| Inputs | Mini-DIN |
| Accuracy (Temperature) | 0.3°C |
| Weight (Metric) | 0.63 kg |
Mettler Toledo™ FiveEasy™ F30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
| Resolution (Conductivity) | Automatic range |
|---|---|
| Memory | Current calibration |
| Range (Conductivity) | 0.01 μS/cm to 200 mS/cm |
| Range (TDS) | 0 mg/L to 300 mg/L |
| Measurement Modes | Conductivity |
| Calibration | One point calibration with three predefined standards |
| Range (Salinity) | 0 to 42 psu |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
| Display Type | LCD |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±0.5% of the measured value |
| Model | F30 |
| Frequency | 50/60Hz |
| Data Points | 200 |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -5°C to +105°C |
| Inputs | Mini-DIN |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
Thermo Scientific™ Orion™ Pro Star EC212 Conductivity Bench Meter with Stand
Designed to provide accurate and reliable conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star EC212 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature,Resistivity with Temperature |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Data Points | 10,000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Inputs | 8-pin MiniDIN for conductivity with ATC |
| Accuracy (Temperature) | ±0.3°C, ±0.5 °F |
| Weight (Metric) | 1 kg |
| Calibration Points (Conductivity) | 1 to 5 points |
| Warranty | 2 year meter warranty |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | Conductivity, TDS, Salinity, Temperature |
| Calibration Points | 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| IP Rating | IP54 |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | EC212 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Backlight Option | Yes |
| Temperature Range (English) | -22°F to +266°F |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -30°C to +130°C |
| Methods | 10 |
METTLER TOLEDO™ SevenExcellence™ S700 Conductivity Benchtop Meter
The S700 meter measures conductivity, resistivity, TDS, and salinity. Its capabilities can be expanded with additional modules to measure pH, dissolved oxygen, ISE, BOD, Redox/ORP, and ISFET. Features an intuitive touchscreen and the ability to create measurement shortcuts.
| Calibration Points | 13 Pre defined and 20 user defined standard |
|---|---|
| Temperature Compensation | 20°C |
| Range (Resistivity) | 0.01 to 100 megohm/cm |
| Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
| Accuracy (Conductivity) | ±0.5% |
| Sensor Types | Conductivity |
| Data Points | At least 20000 data points, 250 analyses |
| Range (TDS) | 0.001 mg/L to 1000 g/L |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -30°C to +130°C |
| Inputs | Integrated interfaces (USB, RS232 and Ethernet) |
| Accuracy (Temperature) | ±0.1°C |
| Range (Salinity) | 0 to 80 psu |
METTLER TOLEDO™ SevenCompact™ S230 Conductivity Benchtop Meter
The S230 meter measures conductivity, resistivity, salinty, and TDS. A simple and durable interface with only 2 buttons makes this meter easy to use, and results can be captured by a printer with a time and date stamp. Available as meter only or ready-to-use kits for specific applications.
| Range (Resistivity) | 0 to 100 megohm/cm |
|---|---|
| Resolution (Conductivity) | 0.001 to 1 |
| Range (Conductivity) | 0.001 μS/cm to 1000 mS/cm |
| Wattage | 10 w |
| Range (TDS) | 0.00 mg/L to 1000 g/L, autoscaling |
| For Use With (Application) | Routine measurements, sample analysis, data handling, data archiving |
| Range (Salinity) | 0 to 80 psu |
| Calibration Points | 13 Pre defined and 1 user defined standard |
| Temperature Compensation | Linear, non-linear, off, pure- water - reference temperature 20° or 25°C |
| Display Type | TFT |
| Voltage | 9/12 V |
| Accuracy (Conductivity) | ±0.5% |
| Data Points | 1000 |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -30.0°C to +130°C (MTC), -5.0°C to +130.0°C (ATC) |
| Accuracy (Temperature) | ±0.1°C |