Cytiva Disposable PD-10 Desalting Columns
Use for desalting and buffer exchange, as well as removal of low-molecular weight compounds. Cytiva Life Sciences™ Disposable PD-10 Desalting Columns provide fast, high-recovery.
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva HyClone™ Dulbecco's Phosphate Buffered Saline, Solution
Buffer cell culture with PBS in solution.
| Regulatory Status | RUO |
|---|---|
| Content And Storage | 15° to 30°C |
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | Dulbecco's Phosphate Buffered Saline |
| Form | Liquid |
| Endotoxin Level | ≤0.025EU/mL |
| pH | 7 to 7.6 |
| Shelf Life | 24 Months |
| Certifications/Compliance | Manufactured under cGMP and ISO 9001 certified facilities |
| For Use With (Application) | Serves as an irrigating, transporting or diluting fluid while maintaining cell tonicity and viability for a limited period of time |
| Osmolality | 276±10mOsm/kg H2O |
| Sterility | Sterile |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Ficoll-Paque™ PLUS Media
Recognized standard in laboratories worldwide for isolation of human lymphocytes from peripheral blood. Cytiva™ Ficoll-Paque™ PLUS Media maintains the viability and a representative distribution of B and T lymphocytes.
| Content And Storage | 4–30°C |
|---|---|
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| Endotoxin Level | < 0.12 EU/mL |
| Shelf Life | 3 years |
| For Use With (Application) | Cell Isolation |
| Sterility | Sterile |
| Density | 1.078 g/mL |
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |
Cytiva HisTrap™ HP Prepacked Columns
Purify histidine-tagged proteins directly from homogenized, unclarified cells. Cytiva HisTrap™ HP Prepacked Columns are prepacked with Ni Sepharose™ High Performance and designed for simple, high-resolution purification of histidine-tagged proteins by immobilized metal ion affinity chromatography (IMAC).
| Flow Rate | 4 mL/min. (1 mL), 5 mL/min. (5 mL) |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C |
| Description | HisTrap HP are nickel-charged IMAC columns for high resolution his-tagged protein purification with high binding capacity for maximized recovery. |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Material | Polypropylene |
| Support Type | 6% Highly Cross-linked Agarose |
anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody, Cytiva
Highly species-specific anti-Mouse IgG. Cytiva Lifescience™ anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody is designed for applications such as protein blotting, ELISA and immunocytochemistry.
| Antigen | IgG, Whole Molecule |
|---|---|
| Purification Method | Affinity Purified |
| Host Species | Sheep |
| Conjugate | HRP |
| Classification | Monoclonal |
| Isotype | IgG |
| Primary or Secondary | Secondary |
| Content And Storage | 15° to 30°C |
|---|---|
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | Phosphate Buffered Saline (PBS) |
| Form | Liquid |
| Without Additives | No Calcium,No Magnesium,No Phenol Red |
| Endotoxin Level | =1.0EU/mL |
| pH | 7.0 to 7.2 |
| Certifications/Compliance | cGMP and ISO 9001:2000 Guidelines |
Cytiva Whatman™ Benchkote Surface Protector Sheets
Minimize mess and contamination during spills. Whatman™ Benchkote material has a high-quality, smooth, absorbent lab paper layer that soaks up liquid spills. A second laminated polyethylene layer prevents flow-through to the working surface.
| Length (Metric) | 460 mm |
|---|---|
| Product Type | Surface Protector |
| Material | Polyethylene |
| Width (Metric) | 570 mm |
| Dimensions (L x W) | 460 x 570mm |
Cytiva NAP™ Columns, NAP-5
Use for rapid and efficient purification of DNA and oligonucleotides (>10-mer) in less than 15 minutes by gravity flow. Cytiva Life Sciences™ illustra™ NAP™ Columns are disposable columns prepacked with Sephadex™ G-25 DNA Grade
| Includes | Complete step-by-step protocol identifying the fixed volumes needed for equilibration, washing and sample elution |
|---|---|
| Product Type | NAP-5 |
| For Use With (Application) | Rapid and efficient purification of DNA and Oligonucleotides |
anti-Rabbit IgG, peroxidase-linked species-specific whole antibody (from donkey) Secondary Antibody, Cytiva
A highly species-specific anti-Rabbit IgG. Cytiva Lifescience™ anti-Rabbit IgG, peroxidase-linked species-specific whole antibody (from donkey) Secondary Antibody is used with Amersham™ ECL Western Blotting detection reagents.
| Antigen | IgG |
|---|---|
| Purification Method | Affinity Purified |
| Host Species | Donkey |
| Conjugate | HRP |
| Classification | Monoclonal |
| Isotype | IgG |
| Primary or Secondary | Secondary |
| Thickness (Metric) | 435 μm |
|---|---|
| Flow Rate | 47 sec./100mL |
| Particle Retention | 1.5 μm |
| Type | RTU Filter for Total Suspended Solids Analysis |
| Temperature (English) Max. | 1022°F |
| Description | Our Whatman glass microfiber filter papers in grade 934-AH RTU have been pre-washed, dried (or ignited), cooled, desiccated and weighed, which eliminates the pre-treating steps that are otherwise required by the US EPA Laboratory Standard Method 2540 part |
| Thickness (English) | 0.017 in. |
| Temperature (Metric) Max | 550°C |
| Quantity | 100 pieces |
| Grade | 934-AH RTU |
| Material | Borosilicate Glass |
| For Use With (Application) | Monitoring of rivers, lakes and coastal waters |
| Waterflow Rate | 341 mL/min |
Cytiva HisTrap™ FF Columns: 16 x 25mm
Use for optimized purification of histidine-tagged proteins directly from homogenized, unclarified cells by immobilized metal ion affinity chromatography (IMAC). Cytiva Life Sciences™ HisTrap™ FF Columns: 16 x 25mm is a ready-to-use column, prepacked with precharged Ni Sepharose™ 6 Fast Flow.
| Flow Rate | <20 mL/min. |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C, 20% Ethanol |
| Diameter (English) Inner | 0.6 in. |
| Description | HisTrap FF is a ready-to-use column, prepacked with precharged Ni Sepharose 6 Fast Flow for preparative purification of histidine-tagged recombinant proteins by immobilized metal ion affinity chromatography (IMAC). |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Diameter (Metric) Inner | 16 mm |
| Material | Polypropylene |
| Support Type | 6% Cross-linked Agarose |
Cytiva Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa
Processes sample loads in one-third the time. Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa provide a faster and easier way to remove particulates from samples being prepared for HPLC and UHPLC analysis.
| For Use With (Application) | Routine HPLC/UHPLC analysis; Composite assays; Content uniformity; Protein precipitation; Solubility testing; Dissolution testing; Sample filtration; Standard robotics on HPLC instruments with sensitive needles, allowing for higher throughput; Light sen |
|---|