Glass Fiber Filters and Prefilters
- (103)
- (56)
- (1)
- (15)
- (1)
- (137)
- (1)
- (1)
- (9)
- (2)
- (2)
- (14)
- (31)
- (45)
- (25)
- (10)
- (14)
- (4)
- (1)
- (23)
- (41)
- (65)
- (4)
Filtered Search Results
Sartorius Glass Fiber (GF) Pre-filters, No Binder
Use in gravimetric analyses and as a depth filter for sterile filtration. Sartorius Glass Fiber (GF) Pre-filters, No Binder are made of borosilicate glass microfibers and combine fast flow rates with high load capacity. Ideal for relatively clean solutions, as it retains very fine particles.
Sartorius Extra Thick Glass Fiber (GF) Pre-filters
Glass fiber prefilters, depth pre filters, for larger totally filterable volumes in clarification and sterile filtration.
| Type | Glass Microfiber Filter |
|---|---|
| Temperature (English) Max. | 932°F |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Material | Borosilicate Glass Microfiber |
| Filter Type | Net Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Prefiltration of clean solutions such as tissue culture media |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Sartorius MGA Grade Glass Microfiber Filters w/o Binder
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Filtration Time | 40 sec. |
| Air Resistance | 36mbar |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Sample Volume | 435 mL |
| Grade | MGA |
| Material | Borosilicate Glass Microfiber |
| For Use With (Application) | Clarification of buffer and reagent solutions |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.25 mm |
| Type | Glass Microfiber Filter |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Thickness (English) | 0.009 in. |
| Filter Type | Net Filter |
Sartorius MGF Grade Glass Microfiber Filters w/o Binder
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Air Resistance | 145mbar |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Sample Volume | 135 mL |
| Grade | MGF |
| Material | Borosilicate Glass Microfiber |
| For Use With (Application) | Critical analyses in which impurities can be washed out of the filter |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.4 mm |
| Type | Glass Microfiber Filter |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Thickness (English) | 0.015 in. |
| Filter Type | Net Filter |
Sartorius MGG Grade Glass Microfiber Filters w/o Binder
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
| Particle Retention | 1.5 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Filtration Time | 38 sec. |
| Air Resistance | 32mbar |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Sample Volume | 570 mL |
| Grade | MGG |
| Material | Borosilicate Glass Microfiber |
| For Use With (Application) | Ideal for critical analyses in which impurities can be washed out of the filter |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.28 mm |
| Type | Glass Microfiber Filter |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Thickness (English) | 0.01 in. |
| Filter Type | Net Filter |
Sartorius Glass Fiber (GF) Pre-filters
Use as a depth filter for larger totally filterable volumes. Sartorius Glass Fiber (GF) Pre-filters are made of borosilicate glass microfibers and are ideal for use as a pre-filter in clarification and sterile filtration. Available in a range of filter disc diameters.
| Particle Retention | 2.6 μm |
|---|---|
| Temperature (English) Max. | 428°F |
| Temperature (Metric) Max | 220°C |
| Color | White |
| Grade | 13400 |
| Material | Borosilicate Glass Microfiber |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Used as a depth prefilter high particle loading capacity |
| Sterility | Non-sterile |
| Thickness (Metric) | 550 μm |
| Flow Rate | 295 to 381mL/min. |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Autoclavable | Autoclavable |
Sartorius MGC Grade Glass Microfiber Filters without Binder
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Binder free MGC Grade Glass Microfiber Filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
| Particle Retention | 1.2 μm |
|---|---|
| Temperature (English) Max. | 932°F to 1022°F |
| Filtration Time | 66 sec. |
| Air Resistance | 51 mbar |
| Temperature (Metric) Max | 500°C to 550°C |
| Color | White |
| Sample Volume | 320 mL |
| Grade | MGC |
| Material | Borosilicate Glass Microfiber |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.25 mm |
| Type | Glass Microfiber Filter |
| Format | Disc |
| For Use With (Equipment) | Filtration Systems |
| Thickness (English) | 0.009 in. |
Sartorius MGD Grade Glass Microfiber Filters w/o Binder
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Merck Woven Mesh Spacer, Dacron, 124 mm
Woven mesh spacers are placed between filters in serial filtration to prevent the downstream screen filter from 'blinding' the upstream filter pores. They increase flow rate & throughput.
Fisherbrand™ Microglass Fiber Filters, Grade 261
Made with 100% borosilicate micro-glass fibers and are binder free. Fisherbrand™ Microglass Fiber Filters are particularly suitable for micro-filtration because of very fine fibers.
| Thickness (Metric) | 0.26 mm |
|---|---|
| Pore Size | 1.2 μm |
| Basis Weight | 52 g/m2 |
| Format | Disc |
| Filtration Time | 100 sec. |
| Temperature (Metric) Max | 500°C |
| Grade | 261 |
| Material | Borosilicate Glass |
| For Use With (Application) | Filtration of industrial water, ligand binding test, Proteins filtration, radio-immuno tests, suspended solids in water, drinking water filtration, cells collection |
Fisherbrand™ Microglass Fiber Filters, Grade 259
Made with 100% borosilicate micro-glass fibers. Fisherbrand™ Microglass Fiber Filters, Grade 259 are non-hygroscopic and biologically inert. They show chemical resistance to most solvents and reagents (except hydrofluoric acid).
| Thickness (Metric) | 0.26 mm |
|---|---|
| Pore Size | 1.6 μm |
| Basis Weight | 52 g/m2 |
| Format | Disc |
| Filtration Time | 60 sec. |
| Grade | 259 |
| Material | Borosilicate Glass |
Munktell Filtrak™ Grade MGB Glass Fiber Pre-Filters
For the filtration of suspended solids in water, waste water analysis in large volumes.
Advantec™ Grade GF75 Glass Fiber Filters
Grade GF75 Glass Fiber Filters for analytical or gravimetric studies.
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A Sheets
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A Sheets are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Sheet |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Sheet |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |