Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Thickness (Metric) | 260 μm |
|---|---|
| Flow Rate | 10.5 sec./100 mL |
| Particle Retention | 1.2 μm |
| Temperature (English) Max. | 932°F |
| Basis Weight | 53 g/m2 |
| Shape | Circle |
| Format | Disc |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Thickness (English) | 0.01 in. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Waterflow Rate | 105 mL/min |
Cytiva Whatman™ Qualitative Filter Paper: Grade 1 Circles
Covers a wide range of laboratory applications and is frequently used for clarifying liquids. Whatman™ Qualitative Filter Paper: Grade 1 Circles are widely used standard grade filter papers for routine applications with medium retention and flow rates.
| Thickness (Metric) | 180 μm |
|---|---|
| Flow Rate | 57mL/min. (water) |
| Particle Retention | >11 μm |
| Basis Weight | 87 g/m2 |
| Format | Disc |
| Airflow Rate | 13sec./100mL/sq. in. |
| Grade | Grade 1 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 150 sec. |
| For Use With (Application) | A widely used standard grade filter paper for routine applications with medium retention and flow rate. It covers a wide range of laboratory applications and is frequently used for clarifying liquids. |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Cytiva Percoll™ Centrifugation Media
For separation of cells, subcellular particles, and larger viruses (down to approx. 70S) under gentle conditions that preserve viability and morphological integrity. Cytiva™ Percoll™ Centrifugation Media Percoll is composed of colloidal silica coated with polyvinylpyrrolidone (PVP).
| Viscosity | 15cP |
|---|---|
| Content And Storage | 4–30°C |
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| pH | 8.5 to 9.5 |
| Shelf Life | 5 years |
| For Use With (Application) | Cell Isolation |
| Density | 1.135 g/mL |
| Osmolality | < 25 mOsm/kg |
Cytiva Pharmalyte™ Carrier Ampholytes
Use in Isoelectric focusing. Cytiva Pharmalyte™ Carrier Ampholytes prepared by the co-polymerization of glycine, glycylglycine, amines, and epichlorohydrin, are available in five broad-range and four narrow-range pH intervals.
| For Use With (Equipment) | PhastSystem Automated Electrophoresis Unit |
|---|---|
| Product Type | Pharmalyte Carrier Ampholyte |
| Form | Liquid |
| Formulation | Co-polymerization of Glycine, Glycylglycine, Amines and Epichlorohydrin |
| Color | Colorless to Light Yellow |
| Quantity | 25mL |
| Storage Requirements | 2° to 8°C |
| For Use With (Application) | IEF |
Cytiva NAP™ Columns, NAP-5
Use for rapid and efficient purification of DNA and oligonucleotides (>10-mer) in less than 15 minutes by gravity flow. Cytiva Life Sciences™ illustra™ NAP™ Columns are disposable columns prepacked with Sephadex™ G-25 DNA Grade
| Includes | Complete step-by-step protocol identifying the fixed volumes needed for equilibration, washing and sample elution |
|---|---|
| Product Type | NAP-5 |
| For Use With (Application) | Rapid and efficient purification of DNA and Oligonucleotides |
Cytiva HyClone™ Dulbecco's Phosphate Buffered Saline, Solution
Buffer cell culture with PBS in solution.
| Regulatory Status | RUO |
|---|---|
| Content And Storage | 15° to 30°C |
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | Dulbecco's Phosphate Buffered Saline |
| Form | Liquid |
| Endotoxin Level | ≤0.025EU/mL |
| pH | 7 to 7.6 |
| Shelf Life | 24 Months |
| Certifications/Compliance | Manufactured under cGMP and ISO 9001 certified facilities |
| For Use With (Application) | Serves as an irrigating, transporting or diluting fluid while maintaining cell tonicity and viability for a limited period of time |
| Osmolality | 276±10mOsm/kg H2O |
| Sterility | Sterile |
anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody, Cytiva
Highly species-specific anti-Mouse IgG. Cytiva Lifescience™ anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody is designed for applications such as protein blotting, ELISA and immunocytochemistry.
| Antigen | IgG, Whole Molecule |
|---|---|
| Purification Method | Affinity Purified |
| Host Species | Sheep |
| Conjugate | HRP |
| Classification | Monoclonal |
| Isotype | IgG |
| Primary or Secondary | Secondary |
Cytiva Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns
For size exclusion chromatography and analysis of proteins with molecular weights between 10,000 and 600,000. Cytiva Lifescience™ Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns are designed for small scale preparative purification.
Cytiva MicroSpin™ G-25 Columns
Use for the rapid purification of DNA >10 base pairs in length in a wide range of applications. Cytiva Life Sciences™ llustra™ MicroSpin™ G-25 Columns are ideal for desalting, buffer exchange, and removal of unincorporated nucleotides from end-labeled oligonucleotides.
Cytiva Whatman™ Qualitative Grade Plain Circles and Sheets - Grade 3
Used for high precipitate capacity and increased wet strength. Whatman™ Qualitative Grade Plain Circles and Sheets - Grade 3 provide double the thickness of Whatman Grade 1.
| Thickness (Metric) | 390 μm |
|---|---|
| Grade | Grade 3 |
| Material | Cellulose |
| For Use With (Application) | A standard grade filter used in qualitative analytical techniques to determine and identify materials. For use in büchner funnels. |
Cytiva HisTrap™ FF Columns: 16 x 25mm
Use for optimized purification of histidine-tagged proteins directly from homogenized, unclarified cells by immobilized metal ion affinity chromatography (IMAC). Cytiva Life Sciences™ HisTrap™ FF Columns: 16 x 25mm is a ready-to-use column, prepacked with precharged Ni Sepharose™ 6 Fast Flow.
| Flow Rate | <20 mL/min. |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C, 20% Ethanol |
| Diameter (English) Inner | 0.6 in. |
| Description | HisTrap FF is a ready-to-use column, prepacked with precharged Ni Sepharose 6 Fast Flow for preparative purification of histidine-tagged recombinant proteins by immobilized metal ion affinity chromatography (IMAC). |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Diameter (Metric) Inner | 16 mm |
| Material | Polypropylene |
| Support Type | 6% Cross-linked Agarose |
Cytiva Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Processes sample loads in one-third the time. Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa provide a faster and easier way to remove particulates from samples being prepared for HPLC and UHPLC analysis.
| For Use With (Application) | Routine HPLC/UHPLC analysis; Composite assays; Content uniformity; Protein precipitation; Solubility testing; Dissolution testing; Sample filtration; Standard robotics on HPLC instruments with sensitive needles, allowing for higher throughput; Light sen |
|---|